3051CD pressure transmitter  Features:


±≤ 0.2% Static Accuracy

316L SST diaphragms & flanges

±≤ 0.25%  stability

HART Protocol


Electrical

Power Supply  :12-45 Vdc with no load

Output            :4-20 mAdc linear

Zero & Span Adjust : Continuous

Warm Up : 2 seconds max 

(with minimum damping)

Power Supply Effect : Less than +/-0.005% of span/volt input change

Load Effect No effect except power across transmitter

EMI/RFI

Less than +/- 0.1% FSO;

20 to 1,000 MHz; @ 30 V/m


Performance :

Static Accuracy ± 0.2% of calibrated span

Base Pressure Effect

On Zero ± 0.25% FSO standard range per 2,000 psi

On Span +/-0.5% of reading for 0-30 inwc


+/- 0.25% if rdg per 1,000 psi; 0-150 inwc & 750 inwc

Temperature Effect +/- 2.5% FSO Total Error Band for 0-30 inwc

  +/- 1.5% FSO Total Error Band; 0-150 inwc & 750 inwc

Vibration Effect 0.05% FSO per g to 200 Hz in any axis

Mounting Effect Zero shifts up to 1 inwc depending on orientation

Stability +/- 0.2% FSO per annum