E-mail: newsales12@vip.163.com
Tel: +86-15829050512
Contact Us

Address: Unit3.Building1, No.3 Courtyard, Pailou Alley Dongguan South Street, Beilin Distrct, Xi'an, Shaanxi, China

Tel: +86-15829050512

Fax: +86-029-82490435

E-mail:newsales12@vip.163.com

Home > Knowledge > Content

Rosemount 1151 Pressure transmitter Manufacturer

Rosemount 1151 Pressure transmitter Manufacturer 


Static Pressure Limits

Transmitters operate within specifications between the following

limits:


Rosemount 1151DP

0.5 psia to 2,000 psig (3.45 kPa to 13790 kPa).

Rosemount 1151HP

0.5 psia to 4,500 psig (3.45 kPa to 31027 kPa).

Rosemount 1151AP

0 psia to the URL.

Rosemount 1151GP

0.5 psia (3.45 kPa) to the URL.

Rosemount 1151LT

Limit is 0.5 psia (3.45 kPa) to the flange rating or sensor rating,

whichever is lower.


Overpressure Limits

Transmitters withstand the following limits without damage:

Rosemount 1151DP

0 psia to 2,000 psig (0 to 13790 kPa).

Rosemount 1151HP

0 psia to 4,500 psig (0 to 31027 kPa).

Rosemount 1151AP

0 psia to 2,000 psia (0 to 13790 kPa).

Rosemount 1151GP

Ranges 3–8: 0 psia to 2,000 psig (0 to 13790 kPa).

Range 9: 0 psia to 4,500 psig (31027 kPa).

Range 0: 0 psia to 7,500 psig (51710 kPa).

Rosemount 1151LT

Limit is 0 psia to the flange rating or sensor rating, whichever

is lower. See Table 4.


Basic feature :

Proven field performance and reliability :


· Commitment to continuous improvement

· Reference accuracy of 0.075%

· Two-year stability of 0.1%

· Rangeability of 50:1