Rosemount 8700 Water Electromagnetic Flowmeter Alibaba recommend supplier

Rosemount 8700 Water Electromagnetic Flowmeter Alibaba recommend supplier


Basic Info.

Model NO.:8730E 8705

Accuracy:±0.2-0.5%

Main Application:Water, Wastewater, Corrosive Liquid/Gas, Acid

Size:Dn10-2000

Sensor:Tube/Flange

Application:Industrial Production

Type:Electromagnetic Flow Meter

Measuring Media:Liquid

Measuring Principle:Electrical Principles

Measurement Object:Closed Pipeline

Certification:CE, SGS, ISO

Package:Wooden

Specification:CE, ISO

Trademark:JH

Origin:Shanghai

Connection:Flange

Output:Pulse+4-20mA

Lining Materia:PTFE

Electrode Materia:Ss316L

Body Material:Ss304

Power Supply:220V

Model:Integrated Type

HS Code:902610000

Production Capacity:5000PCS/M

Product Description

Magnetic Flowmeter

Measuring Principles:The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.

Main Applications:
Electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry.

Features:
-Large choice of liner materials like 316L,F4, PTFE, F46, Fs and rubber.
-DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
-Electric conductivity of medium can be used for detection of product change.
-No additional pressure loss electromagnetic flowmeter.
-No moveable parts and long working life.
-Site digital LCD displays instantaneous flow, accumulative flow, flow rate.
-Various output method, like 4-20mA, 0-5V, RS485 and pulse.
-Compact, split and plug-in types optional.
-Change the grounding as the third electrode.

Parameters:

DN

10mm~~2000mm

PN

PN10 , PN16 , PN25 , PN40 , PN63 , PN100 , PN160 , PN250 , PN420

Electrode material

SS316L

Lining material

PTFE ,FS ,rubber or customize

Medium tem

0~70°C , max is  180°C

Shell material

carbon steel

Protection grade

IP65 , IP67   and IP68

Connection

all applys(flange & screw thread)




Converter technical data:

Current output

4~20Ma

Frequency output

pulse :
High level=external power supply-1V
External volts≤30 V
Low level ≤ 0.5V
Load current ≤ 50 mA
Max.frequency output :5KHz .
Frequency of pulse output:  0~5Hz .

Display

With 8digit LCD display

Display unit

Instantaneous flow units  : m 3  /h ,  m 3  /m , m 3  /s , L/h , L/m ,  L/s , G/h , G/m , G/s .  Total flow units: m 3 , L , G .

Communication

MODBUS protocol ( optional ) or HART ( optional )

Protection grade

IP65

Power supply

220 V AC +20/-60%  , 50/60 Hz , 24 V DC +50/- 25%  , max.10VA

EMC radiation standard

EN 61326-1 : 2006  (BS EN50081-1)

EMC anti-jimming standard

EN 61326-1: 2006 (BS EN50082-1)

CE security

EN 61010-1 : 2001

Ambient temp.

5~55°C

Ambient humidity

<85 % r.h. (non   co n densation)