Rosemount 3051C Differential Pressure Transmitter China Supplier
May 07, 2016

Rosemount 3051C Differential Pressure Transmitter China supplier 


Feature :


Model NO.: Rosemount 3051c


Product Description

Specifications of Rosemount 3051c Differential Pressure Transmitter: 


Output: 4-20 mA with digital signal based on HART Protocol; Low Power, 1-5 V DC with digital signal based on HART Protocol; Low power, 0.8-3.2 V DC with digital signal based on HART Protocol, optional 

Range: 0-0.01 in H2O to 0-2000 psid 

Accuracy: 0-1: +/-0.1% of span 

Power: 4-20 mA: 10.5-55 V DC with no load Low Power: 6-12 V DC with no load 

Materials: Sensor Wetted Parts: SST, Hastelloy, Monel, Tantalum 

Fluid: Sensor fill fluid: Silicone, Inert (Halocarbon) 

Mounting: Coplanar and Traditional flanges and Adapters: Cadmium and Nickel-plated CS, 316 SST


Use correctly :

A pressure sensor process shall consider the following:


1, to prevent the corrosive medium in contact with the transmitter or overheating;


2, to prevent the waste deposited in the conduit;


3, when the measurement of liquid pressure, the pressure taps should be opened in the process side of the line, to avoid precipitation slag accumulation;


4, when measuring the gas pressure, the pressure taps should be opened at the top of the flow line, and the transmitter should be installed in the upper part of the flow line, so that the accumulation of liquid flow easily injected the pipeline;


5, connecting pipe should be installed in a small local temperature fluctuations;


6, measuring high temperature steam or other media, must be connected to add a buffer tube (coil) condenser, etc., should not make the transmitter operating temperature limits are exceeded;


7, when the winter frost occurs, the transmitter is installed in the outdoor freezing measures must be taken to avoid the liquid inside the mouth due to the impulse ice volume expansion, leading to the sensor is damaged;


8, when the measurement of liquid pressure, the installation location of the transmitter to avoid the impact of the liquid (water hammer phenomenon), in order to avoid overvoltage damage sensor;


9, when wiring the cable through the waterproof connector (accessory) or about sex by tightening the seal nut to prevent rainwater leakage through the cable into the transmitter within the housing.