Basic Info

  • Model NO.: R-series 

  • Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil

  • Sensor: Tube/Flange

  • Type: Coriolis Mass Flow Meter

  • Measuring Principle: Mechanics

  • Certification: CE, RoHS, SGS, ISO

  • Flow Range: 0-550 T/H

  • Medium Temperature: -40-350c

  • Work Pressure: 4MPa,30MPa

  • Trademark: JH

  • Origin: USA

  • Accuracy: ±0.2-0.5%

  • Size: Dn1-150

  • Application: Industrial Production

  • Measuring Media: Liquid

  • Measurement Object: Closed Pipeline

  • Body Material: Stainless Steel

  • Power Supply: 24VDC

  • Output: Pulse/4-20mA/RS485

  • Protection Class: IP65

  • Specification: CE, ISO

  • HS Code: 9026100000

Product Description

The meters are designed for unsurpassed performance in even the harshest operating environments. They have no moving parts, and any special mounting or flow conditioning requirements. Every meter is available with stainless steel wetted parts and a wide variety of process connections to meet your every need.

-Using the world's most advanced second generation transmitter technology - DSP technology, higher precision, wider range, more simple structure, more stable operation.

-Measurement of high pressure gas (such as CNG compressed natural gas (LNG), low temperature liquids such as liquefied natural gas, liquid nitrogen).

-Using high-precision processing technology, ensure the sensor quality, zero stability.

-Using digital signal processing (DSP) technology, metering system host through the 485
communication, the relevant parameters, to obtain the required such as: mass flow, volume flow rate,temperature, density, the state information.

-Through the debugging software or manual debugging device can read the fault code, solving the problem of inconvenient meter using the staff more comprehensive, troubleshooting
-Support the standard industrial control communication protocol ModbusRTU, easy configuration and use.

-According to user needs, mass flowmeter in design and manufacture of special specifications and has special function, tailored to the user.

Technical parameters:

Mass flow accuracy±[0.2% +(zero stability /flow rate×100%)
Mass flow repeatability±(1/2) ×[0.2% +(zero stability /flow rate×100%)
Density range0.2 g/cm3~3.5g/cm3
Density accuracy±0.002g/cm3
Temperature range-60C-+200C
Temperature accuracy±1C
Output of current loop4mA~20mA
Output of frequency/pulse0Hz~10kHz
Contactor capacity of a Batch Control relay24V/0.1A
Explosion-proofEssential safety:Exib[ib]IIBT4
Contactor formnormal open
Environmental Specifications
Temperature range of fluid-40C-+200C
Environmental temperature range0C-+40C
Environmental humidity≤90% RH, non condensation
Atmospheric pressure range86kPa~106kPa
Power supply of transmittersEssential safety Voltage: AC(220±10%)V,(50±5%)Hz
Composite Voltage: DC (24±10%) V


SpecsLine Sizes (mm)Flow Range (t/h)Calibration Range (t/h)Max. Tube Pressure (MPa)Zero Stability (t/hr)Velocity  Parameter