E-mail: newsales12@vip.163.com
Tel: +86-15829050512
Contact Us

Address: Unit3.Building1, No.3 Courtyard, Pailou Alley Dongguan South Street, Beilin Distrct, Xi'an, Shaanxi, China

Tel: +86-15829050512

Fax: +86-029-82490435

E-mail:newsales12@vip.163.com

Home > News > Content

News

Rosemount Mangnetic Flowmeter 8700 series Maufacturer China supplier Exporter
Jun 11, 2016

Basic Info.

Model NO.:8700 Accuracy:&#0.2-0.5%
Size:DN10-200Sensor:Tube/Flange
Type:Electromagnetic Flow MeterMeasuring Media:Liquid
Measuring Principle:Electrical PrinciplesPackage:Cartons/Wooden Box
Specification:DN10-DN200Trademark:FLOWTECH
Origin:ChinaDn10-Dn2000:1/2inch-80inches
HS Code:902610000Production Capacity:500PCS/Month

Product Description

Rosemount Mangnetic Flowmeter

Conductivity mediums like acid, alkali, juice, milk, water, waste water, etc
Economic low cost digital flowmeters

Rosemount Mangnetic Flowmeter  flowmeter is an inductive apparatus to measure the flow volume of electric medium in the tube. The flowmeter composes of sensor and converter, the flowmeter design is adopted of SCM built-in technology to realize digital inciting magnetism the SCM connects CAN bus-mastering in the electromagnetic flowmeter at the same to time. The electromagnetic flowmeter can not only be read straightly but also output 4-20mA current signal for purpose of memory, adjustment and control, the flowmeter is extensively used in industry technology and administration department such as chemical industry, environmental protection, metallurgy, medicine, paper making and water supply, etc.


Technical data
Gauge preciseness: Pipe style 0.5 grade, 1.0 grade, insert style 2.5 grade
Measure medium: Two kinds of flowing substances: All of liquids and liquid-solids whose electric conductance ratio is less than 5US/CM
Flow speed range: 0.3-12m/s
Working pressure: 0.6-4.0MPa
Environmental temperature: 0-55C
Medium temperature: PTFE lining less than 150C, rubber lining less than 65C
Anit-explosion signal: Exd IIBT4
Electromagnetic interference: Less than 400A/m
Shell protection: Integration style: IP65, separation style: Sensor IP68, converter IP65
Output signal: 4-20mA, loading resistance 0-750Ω
Transmission output: RS485 or can bus-line
Electrical connection: M20*1.5 female thread, 10 cord hole
Electrical power voltage: DC18-36V, AC85-265V
Maximum power consumption: Less than 15W


In the normal industry application, it is better to set the measured medium speed as 2-4m/s, under the special situation, the minimum speed should be more than 0.2m/s and maxium speed less than 8m/s, if there are solid granules in liquid, the usual speed should be less than 3m/s for purpose to avoid the over-atrition between lining and electrical poles, for viscid liquid, the speed can choose as 2m/s, the fast flow speed makes for the automatic elimination of obstructive substance glued on poles, therefore improve the inspections preciseness.

Paratus selection    
DN Usual full range flow volume selection(m3/h) Integration  Partial installation
weights(KG)  weights (KG)

10 0.16,0.2,0.25,0.3,0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5 6 4
15 0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0 6 4
20 0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0 6 4
25 1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0 7 5
32 1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0 9 7
40 2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0 10 8
50 4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,70 12 10
65 ,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120 17 15
80 10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160 17 15
100 16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160,200,250 22 20
125 25.0,30.0,40.0,50,60,80,100,120,160,200,250,300,400 24 22
150 40.0,50,60,80,100,120,160,200,250,300,400,500,600 35 33
200 60,80,100,120,160,200,250,300,400,500,600,800,1000 45 43